O2T - flue gas tester for O2

Flue gas tester for O2

Oxygen measurement directly in the flue gas
Outputssignale for O2-content and flue gas temperature

The flue gas analyser O2T is a transducer for measuring the oxygen content and temperature of the flue gas.

The transmitter operates with a zirconia probe for O2 determination and with a measuring resistor Pt100 for temperature measurement. It is installed directly into the flue gas duct. A gas treatment is not required.

Operating mode:
Measurement mode
Measuring probe – O2 measurement:
Foreign-heated zirconium dioxide probe
Measuring range:
0 … 5% O2
0..10% O2
0 … 20% O2

Output:
0 … 20 mA or 4 … 20 mA
Response time:
<15 s for 90% measured value change
Operational readiness:
Approx. 2 min. After switching on the supply voltage
Exhaust temperature:
Max. 400 ° C, continuous
Permissible fuels:
Residue-free gases and light fuel oil
Tool life:
> 1 year
Testing option:
Test gas connection on electronics housing

Measuring element – Temperature:
Pt100 according to DIN EN 60751
Measuring ranges:
0 … 250 °C or 0 … 400 °C
Output:
0 … 20 mA or 4 … 20 mA
Burden:
Max. 500 Ω

Measurement accuracy – O2 measurement:
± 4 % v.E. + 3 % v.M.

Error limit:
± 4 % v.E. + 3 % v.M.

Error limit:
± 4 % v.E. + 3 % v.M.

Measuring instrument:
Stainless steel pipe, ø 60 mm, 250 mm long with flow pipe 180 mm long
Casing:
Aluminum die-cast for receiving the heating transformer as well as the evaluation electronics. Housing screwed directly to the measuring armature, thermally insulated
Cable gland:
PG11

Dimensions:
120 x 122 x 80

Weight:
Approx. 6 kg

Power supply:
230 Vac

Power consumption:
Approx. 35 VA

EMC:
EN 61000-6-2, EN 61000-6-3, CE-mark

RoHS:
according RoHS-directive 2011/65/EU